屏式过热器 meaning in Chinese
platen superheater
Examples
- The analysis on the tubes burst of division pendant superheater of 600 mw natural circulation boilers
自然循环锅炉屏式过热器爆管分析 - Through macroscopic examination , wall - thickness measurement , and metallographic examination of tube specimen taken from the bursted platen superheater of boiler no . 1 , the causes leading to tube - burst have been analysed
摘要通过对1号炉屏式过热器爆管管样的宏观检验、壁厚测量和金相检验,对爆管原因进行了分析。 - For the limitation of the former soviet union boiler unit heating calculation standard methods in 1973 in the boiler furnace , panel and platen superheater , this paper puts forward the new methods of the boiler heating calculation
分析了前苏联73年锅炉机组热力计算标准方法中炉膛、分隔屏过热器和屏式过热器计算方法的缺陷,初步提出锅炉热力计算新方法。 - In the end of the dissertation , a tube lifetime evaluation software system is developed with the utility of the finite element analysis stress computation and the metallographic tests . the lifetime of the platen superheater tube is evaluated by the software system
最后,综合以上应力解析法、有限元应力计算和余相试验研究开发了管件寿命评估软件系统,并使用该系统综合评估了屏式过热器管段的寿命。 - Results show that the tube - burst is mainly due to the result of tube ' s long term overheating , while the main causes resultsing in overtemperature of the platen superheater are as follows ; ( 1 ) burn - out of superheater ' s pipe - grippers ; ( 2 ) some tube - sections are out of the row ; ( 3 ) unsuitable mode for adjusting the desuperheating water
结果表明:爆管主要是由于管子长期过热所致,而屏式过热器管卡烧损、个别管段出列、减温水调节方式不当是引起屏式过热器超温的主要原因。