供热量 meaning in Chinese
heating load
Examples
- Heating systems in buildings - method for calculation of the design heat load ; german version en 12831 : 2003
建筑物供暖系统.设计供热量计算方法 - The average temperature of supply water and backwater only is single function of extraventricular temperature . so only it can reflect radiator ' s emitting heat , heat net supplying heat and user ' s heat load
只有二次网供回水平均温度是室外温度的单值函数,即它能反映用户热负荷、散热器散热量、热网供热量的大小。 - This thesis gives a fundamental quantitative analysis of the cycle of recuperative gas turbine cogeneration with water injection and mainly discusses the influence of water injection ratio and pressure ratio on the specific power and the amount of heating
本论文对功热并供回热注水燃气轮机热力循环进行了基本定量分析。主要分析了注水率和压比对比功和供热量的影响。 - This experiment include many contents , in a word , that is summer condition experiment , winter condition experiment > summer - winter transition condition experiment and winter - summer transition condition experiment , furthermore summer condition experiment still include flux changing experiment and winter condition experiment still include thermal balance experiment this article dealt with the data of the test , calculating out energy absorbing ( energy discharging ) of buried pipe in winter condition ( summer condition ) , input power of heat pump x heat exchanging of piece buried pipe length x co - efficiency performance ? op ( energy efficiency rate ? er ) and average heat exchanging coefficient ; in additiont this article compares the inlet water temperature and outlet water temperature of underground the first layer and the second layer buried pipe when heat pump was running , the results are that the heat exchanging ability of the second layer buried pipe outgos the first layer buried pipe , and heat exchanging is more stable ; and still analyse earth temperature resuming in the transition season . the results are earth temperature resume fast in the first week when the heat pump runs off
本文测试内容相当多,概括地说就是四个工况的测试,即夏季制冷工况的测试、冬季供热工况的测试、夏?冬过渡季测试和冬?夏过渡季测试;另外在夏季工况的测试中还进行了变流量测试,在冬季工况的测试中还进行了热平衡测试。本文对测试数据进行了处理,计算出了冬(夏)季工况埋管吸(放)热量、热泵空调器供热量(制冷量) 、热泵空调器输入功率、埋管单位管长换热量、供热性能系数(制冷能效比)和平均传热系数等;另外,还比较了热泵运行时地下一二层埋管进出水温度变化情形,得出地下二层埋管换热能力优于地下一层埋管,且换热很稳定;并分析了过渡季地下一二层埋管温度恢复情形,得出热泵系统停机一周内地温恢复特别快。 - Heating centralized is an important thing in the north . whether this is implemented in a large scale has contributed to impove city modern level and ameliorate atmosphere environment . the traditional heating system are two - upright - pipe - parallel system , two - pipe system , single - pipe - stride system etc , whose calculation for heat charge is either by man or by ic installed on the caliduct . therefore , the problem arise that heat provided does n ' t accord with heat charge payed , not secure , and resident have to suffer much
传统的供暖系统有双立管水平式系统、全双管系统、单管跨越式系统等,其计费方式要么为人工计费,要么是利用安装在暖气片上的带电读卡器,这样存在着供热量与收费额匹配不准确、不安全等方面的问题,也使集中供热用户有苦难言。